View the manual for the Honeywell TrueZONE HZ311 here, for free. This manual comes under the category not categorized and has been rated by 1 people with an average of a 7.5. This manual is available in the following languages: English. Do you have a question about the Honeywell TrueZONE HZ311 or do you need help? Ask your question here

Need help?

Do you have a question about the Honeywell and is the answer not in the manual?

Question and answer

Number of questions: 34 Kevin CraigNovember 19, 2022

If you’re using two zones and one thermostat is set to cool and the other is set to heat mode what will the system do?

Same question Type your response here Add my comment
1 comment
Emma of manua.ls i December 19, 2023

The Honeywell TrueZONE HZ311 system is designed to control multiple areas in a heating and cooling system. If one thermostat is set to cool and the other is set to heat, the system will prioritize the thermostat set to cool. It will activate the cooling equipment and adjust the dampers to direct airflow to the cooling area. The thermostat set to heat will not activate the heating equipment and the dampers will remain closed for that area.

This answer is automatically generated

Post reaction Christina AhernNovember 20, 2022

2 of my zones have a red light. It seems like the whole house is not heated. What do I do?

Same question Type your response here Add my comment
1 comment
Emma of manua.ls i December 18, 2023

The Honeywell TrueZONE HZ311 panel has LED indicators that provide information about the system and zone status. Here is the meaning of the LED lights: - HEAT: The LED is solid when the heating is in operation. It blinks when the high limit mode of the DATS reaches 160°F (71 °C). - COOL: The LED is solid when the cooling is in operation. It blinks when the low limit mode of the DATS reaches 45°F (7°C). - FAN: The LED is solid when the fan is in operation. - PURGE: The LED is solid during the purge process, which lasts for 2 minutes at power-up and after a call for heat or cool. It blinks if the DATS sensor has failed, or if the wires are shorted or open. If there is no DATS present, it will blink for 3 minutes at power-up. - ZONE 1, 2, 3: The LED is solid green when the zone is open or opening. It is solid red when the zone is closed or closing. It blinks amber if there is a damper or thermostat short circuit (circuit breaker trip). If two of your zones have a red light and it seems like the whole house is not heated, it indicates that those zones are closed or closing. To resolve this issue, you can try the following steps: 1. Check the dampers in the affected zones to ensure they are fully open. 2. Verify that the thermostats in those zones are set to the desired temperature and are calling for heat. 3. Inspect the wiring connections for any loose or damaged wires. 4. Make sure the TrueZONE HZ311 panel is receiving power and functioning properly.

This answer is automatically generated

Post reaction AcJune 25, 2023

What’s the purge for, and why is the light red? Help!

Same question Type your response here Add my comment
1 comment
Emma of manua.ls i December 16, 2023

The purge function on the Honeywell TrueZONE HZ311 panel is used to save time during installation or troubleshooting. When the zone panel cover is off, you can see the PURGE OVERRIDE button. Pressing this button stops the purge process. The panel will then wait for the next call for heat, cool, or fan. If there are no calls, the panel will remain in idle mode. The red light indicates that the panel is in purge mode. It will flash if there is a sensor failure or if the wires are shorted or open. During power-up, the red light will blink for 3 minutes if there is no DATS (Discharge Air Temperature Sensor) present.

This answer is automatically generated